GivEVC Portal
Sign in to manage your chargers.
We sent a 6 digit code to .
Overview

Add your first charger

Create an onboarding session, then enter the generated OCPP endpoint and password into your charger local admin portal.

Pending Onboarding
Chargers
Status
● Online
EV Charger connected
Power Now
kW
Live charge power
Last Session
kWh
Previous charge
Today
Energy used today
Total Energy
kWh
All time
Charger Status
Vehicle Not Plugged In
Grid Mode
Energy Usage
Last Charge Session kWh
Today kWh
This Month
Total (All Time) kWh
Charger Info
Model
Firmware
Serial
Charge Point ID
IP Address
OCPP Status
Live Readings
Power
Current
Voltage
Charger is offline — settings cannot be changed.

Theme

Choose the display theme for the portal.

Auto Refresh Interval

How often (in seconds) to automatically read configuration and meter values from the charger.

10 s

Log OCPP Commands

Record all automatic GetConfiguration and TriggerMessage MeterValues commands in the activity log. When enabled, the log will grow quickly due to periodic polling.

Charger is offline — settings cannot be changed.
Solar
Charge using surplus solar energy only
Hybrid
Blend solar and grid power for charging
Grid
Charge from the mains grid supply
Charger is offline — settings cannot be changed.
Schedules
Schedule
No schedules configured
Charger is offline — settings cannot be changed.
ID Tags
ID TagAliasExpires AtStatusActions
No ID tags configured
Charger is offline — settings cannot be changed.

Unlock Charging Port

Force the charger to disconnect. Will not work if the EV has locked the connector.

Plug and Go

Start charging automatically as soon as the vehicle is plugged in.

LED State

Turn the charger's front panel indicator LEDs on or off.

Local Modbus Control

Allow third-party devices on the local network to control this charger via Modbus. Charger restarts on change.

Max Charge Current

Limit the maximum current drawn by the charger.

A

Max Energy Per Session

Stop charging once this energy threshold is reached in a single session. Set to 0 to disable.

kWh

DNO Fuse Size

Set the maximum grid import capacity permitted by the installation.

A

Suspend Timeout

How long the charger waits once suspended before sleeping, in minutes. Set to 0 to disable.

CP Voltage Range

Adjust the allowed CP voltage range for charging state 'B'. Min: 7.6–8.0 V, Max: 10.0–10.5 V.

Minimum
V
Maximum
V

CP Voltage

Reads CP voltage and duty cycle directly from the charger via a vendor command.

Voltage
Duty Cycle

Randomised Delay

Regulatory requirement: scheduled charges start after a random delay to reduce grid strain. Range: 600–1800 s.

s

Firmware

Select a firmware version from the list to upgrade, downgrade, or reinstall. The charger will reboot automatically once the update is applied.

Restart Charger

Send a soft restart command to the EV charger.

Factory Reset

Resets all settings on the EV charger back to factory defaults. This cannot be undone.

Activity Log
No activity logged
Power
Real-time power draw · kW / V
Grid Power
EV Charge Power
EV Charge Voltage
Charge Energy
Daily energy delivered · kWh
Error Log
TimestampSerialError CodeDescriptionCleared At
2026-04-10 14:00:55112888535545694TamperDetectionEmergency stop button pressed2026-04-10 14:13:23
2026-04-10 13:59:57112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:57
2026-04-10 13:59:54112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:54
2026-04-10 13:59:53112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:53
2026-04-10 13:59:50112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:50
2026-04-10 13:59:49112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:49
2026-04-10 13:59:47112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:46
2026-04-10 13:59:45112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:45
2026-04-10 13:59:43112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:43
2026-04-10 13:59:41112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:41
2026-04-10 13:59:40112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:40
2026-04-10 13:58:23112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:59:23
2026-04-10 13:58:21112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:58:22
2026-04-10 13:58:20112888535545694TamperDetectionEmergency stop button pressed2026-04-10 13:58:21
1–15 of 35
Chargers

Start a new onboarding session or remove chargers and pending onboarding sessions from this account.

Current Chargers
Pending Onboarding
Account Security

Change your password and manage authenticator app two-factor authentication.

Admin